Battery Calculator
Nominal amp hours are a poor way to compare batteries, because you cannot use all of them and how much you can use differs enormously by chemistry. This works in usable capacity, which is the number that actually determines runtime.
How long will a battery last?
Divide the usable capacity by the current drawn. Usable capacity is the nominal amp hours times the depth of discharge โ about 50% for lead acid and 80 to 90% for lithium. A 100 Ah lithium battery running a 100 W load through an inverter lasts around 10 hours; the same lead acid battery lasts about 5.5.
How to use this calculator
- Enter watts if the load runs through an inverterMains appliances do. The inverter efficiency is then applied, because converting 12 V DC to 230 V AC loses around 10%.
- Enter amps for DC loadsLights, fridges and pumps wired directly to the battery draw DC and bypass the inverter entirely, which is why they are so much more efficient.
- Set the Peukert exponent for lead acidAround 1.2 models the capacity loss at high discharge rates. Leave it at 1.0 for lithium, which is largely immune.
- Compare usable capacity, not nominalA 100 Ah lithium and a 100 Ah lead acid are not comparable products. The breakdown shows the usable figure for both.
Nominal capacity is not what you get
A battery's amp hour rating is the headline number and it is close to useless on its own, for three separate reasons.
The first is depth of discharge. Taking a lead acid battery below about 50% dramatically shortens its life โ a battery routinely drained to 20% might last 200 cycles instead of 700. Lithium iron phosphate tolerates 80 to 90% routinely, and some manufacturers specify 100%.
So a 100 Ah lead acid battery gives you 50 Ah of usable capacity, while a 100 Ah lithium gives 80 to 90. The lithium delivers nearly twice as much energy from the same nominal rating.
That single fact makes comparing amp hours across chemistries meaningless, and it is why lithium batteries that look twice the price are often no more expensive per usable amp hour.
The second reason is Peukert's effect. Lead acid batteries deliver less than their rated capacity when discharged quickly. The rating is typically quoted over 20 hours, and drawing the same battery flat in five hours might yield only 80% of the rated figure.
Lithium is largely immune to this, delivering close to its rated capacity across a wide range of discharge rates. For a high-current application โ an inverter running a kettle, a winch, a starter motor โ that difference is substantial and often decisive.
The third is the inverter. Any mains appliance runs through one, and converting 12 V DC to 230 V AC costs around 10% of the energy. A 100 W load draws about 111 W from the battery, which is 9.3 A at 12 V rather than 8.3.
That is why DC appliances are so much better in an off-grid or leisure setup. A 12 V compressor fridge draws maybe 45 W directly; the equivalent mains fridge through an inverter draws 50 W from the battery for the same cooling, and the inverter's own standby draw runs continuously on top.
Stack the three effects together and the gap between the headline number and reality is large. A 100 Ah lead acid battery running a 100 W mains load has 50 Ah usable, faces a 9.3 A draw, and loses further capacity to Peukert โ perhaps four and a half hours rather than the twelve the nominal rating might suggest.
usable Ah = nominal Ah ร depth of dischargeWorked example: 100 Ah running a 100 W load
Take a 100 Ah 12 V battery and a 100 W mains load through a 90% efficient inverter.
The battery holds 100 ร 12 = 1,200 Wh nominally.
The load draws 100 รท 0.9 = 111.1 W from the battery, which at 12 V is 9.26 A.
For lithium iron phosphate at 90% depth of discharge, usable capacity is 90 Ah, or 1,080 Wh. Runtime: 90 รท 9.26 = 9.7 hours.
For AGM lead acid at 50%, usable capacity is 50 Ah, or 600 Wh. Runtime: 50 รท 9.26 = 5.4 hours.
Apply a Peukert exponent of 1.2 to the lead acid and it falls further, to 4 hours 46 minutes, because 9.26 A is a faster discharge than the 5 A the 20-hour rating assumes.
So the same nominal capacity gives 9 hours 43 minutes or 4 hours 46 minutes depending on chemistry โ a factor of more than two from a headline figure that is identical.
Now run the load directly as DC. A 100 W 12 V appliance draws 8.33 A rather than 9.26. The lithium runtime rises to 10.8 hours and the lead acid to 6 hours, purely by removing the inverter.
Now size for a requirement instead. To run 100 W for 8 hours through an inverter, you need 9.26 ร 8 = 74.1 Ah usable. In lithium at 90% that is an 82 Ah battery; in lead acid at 50% it is 148 Ah.
The lead acid battery is also roughly three times the weight for that capacity โ around 45 kg against 15 โ which matters enormously in a campervan, a boat or anything portable.
On charging: putting the lithium's 90 Ah back at 20 A is nominally 4.5 hours, and about 4 hours 57 minutes once the absorption stage is allowed for. The lead acid needs only 50 Ah replaced, so it finishes in about 3 hours 30 minutes โ but it is storing barely half the energy, and the last 20% is disproportionately slow in lead chemistries.
That charging difference matters for solar. A lead acid bank that only sees five hours of useful sun may never reach full charge, and chronic undercharging sulphates the plates and destroys capacity โ a failure mode lithium does not share.
The same 100 Ah battery by chemistry
| Chemistry | Usable DoD | Usable Ah | Usable Wh | Runtime at 100 W | Typical cycles |
|---|---|---|---|---|---|
| Lithium iron phosphate | 90% | 90 Ah | 1,080 | 9.7 hr | 3,000โ6,000 |
| Lithium, conservative | 80% | 80 Ah | 960 | 8.6 hr | 4,000โ7,000 |
| AGM lead acid | 50% | 50 Ah | 600 | 5.4 hr | 500โ700 |
| Gel lead acid | 50% | 50 Ah | 600 | 5.4 hr | 500โ800 |
| Flooded lead acid | 50% | 50 Ah | 600 | 5.4 hr | 300โ700 |
| Lead acid at 30% DoD | 30% | 30 Ah | 360 | 3.2 hr | 1,200โ1,500 |
| Lead acid at 80% DoD | 80% | 80 Ah | 960 | 8.6 hr | 150โ300 |
The last two rows show the trade-off within lead acid: you can have the capacity or the cycle life, but not both. Discharging to 80% gives lithium-like runtime and destroys the battery in a couple of years of daily use. That trade-off does not exist in the same way for lithium, which is the real reason it dominates leisure and off-grid applications despite the purchase price.
Temperature, ageing and sizing a real system
Cold reduces capacity in every chemistry, typically 20% or more near freezing and considerably worse below. A battery bank sized on a mild-weather calculation will disappoint in January, which is exactly when a heating load is highest.
Lithium has an additional constraint: it must not be charged below 0ยฐC without a built-in heater, though it can be discharged. Charging a cold lithium cell causes lithium plating, which is permanent damage. Most quality LiFePO4 batteries include low-temperature charge protection, and it is worth confirming rather than assuming.
Ageing reduces capacity gradually in both chemistries. A battery at the end of its stated life typically retains 70 to 80% of its original capacity, so sizing with no margin means the system stops meeting the requirement well before the battery is dead.
On cycle life and cost, the comparison that matters is cost per usable kilowatt-hour over the life of the battery, not the purchase price. A lead acid battery at half the price delivering a fifth of the cycles at half the usable depth is considerably more expensive over ten years, and that calculation is what has shifted the leisure and off-grid market.
For sizing a real system, work from an energy audit rather than a single load. List every appliance, its power draw and its hours of use per day, and total the watt hours. Add the inverter's standby consumption, which runs continuously and is easy to forget โ 10 W of standby is 240 Wh a day, which can exceed the fridge.
Then add margin. Two or three days of autonomy is normal for an off-grid system with solar, because consecutive dull days happen and running a bank flat is what kills it.
On charging sources: alternator charging in a vehicle needs a DC-to-DC charger for lithium, because a standard alternator's voltage profile will not fully charge a lithium bank and may overheat if the battery accepts current indefinitely. Solar needs an MPPT controller sized for the array and configured for the chemistry.
A battery management system is essential for lithium and does not exist for lead acid. It protects against over-charge, over-discharge, cell imbalance and temperature extremes, and a lithium battery without one is a fire risk. Quality LiFePO4 batteries have it built in.
Finally, wiring. High currents need appropriately sized cable and correctly rated fusing close to the battery terminal. A 100 A draw through undersized cable is a fire, and the battery will supply hundreds of amps into a short circuit without complaint.
Depth of discharge and cycle life figures are typical rather than universal โ check the manufacturer's specification. Capacity falls with temperature and age, so treat these figures as an upper bound for a new battery in mild conditions.
Assumptions and limitations
- Depth of discharge figures are typical โ manufacturers specify their own
- Assumes a new battery at moderate temperature
- Peukert modelling is a simplification and applies only to lead acid
- Does not model voltage sag under load or the cut-off voltage of the inverter
- Does not account for inverter standby consumption, which runs continuously
- Charge time is an estimate โ the absorption stage varies by charger and chemistry
- Does not size cable, fusing or charge controllers, all of which need separate design
Questions people ask about this in United Kingdom
How long will a battery last?
Usable capacity divided by the current drawn. A 100 Ah lithium running 100 W through an inverter lasts about 9.7 hours.
The same nominal capacity in lead acid gives about 5.4 hours, or 4.6 once Peukert's effect is applied.
Why can't I use all of a battery's capacity?
Because deep discharge shortens life. Lead acid is normally limited to 50%; lithium iron phosphate tolerates 80 to 90% routinely.
That is why comparing nominal amp hours across chemistries is meaningless.
What does an inverter cost me?
Around 10% of the energy. A 100 W mains load draws about 111 W from the battery, or 9.26 A at 12 V.
Running DC appliances directly avoids that entirely, which is why they dominate in leisure vehicles.
What is Peukert's effect?
Lead acid batteries deliver less than their rated capacity when discharged quickly, because the rating assumes a 20-hour discharge.
Lithium is largely immune, which matters for high-current loads like an inverter running a kettle.
Is lithium worth the extra cost?
Usually, on cost per usable kilowatt-hour over the battery's life. It delivers nearly twice the usable capacity and five to ten times the cycles.
It is also about a third of the weight for the same usable energy.
Does cold weather affect capacity?
Yes, typically 20% or more near freezing in any chemistry.
Lithium additionally must not be charged below 0ยฐC without a heater, though it can be discharged โ most quality batteries include protection for this.
How do I size a system properly?
Do an energy audit โ every appliance, its draw and its daily hours โ then add the inverter's standby consumption and two to three days of autonomy.
Sizing on a single load without margin is the most common mistake.
Related United Kingdom calculators
Tools people usually open in the same sitting.
Method, source and review date
- How it is worked out
- Usable capacity with inverter and Peukert adjustments
- Formula used
runtime = (capacity ร depth of discharge) รท current drawn- Checked against
- Standard battery specification practice
- Rates last verified
- Confidence
- Medium
Depth of discharge figures are typical rather than universal โ manufacturers specify their own, and cycle life depends heavily on how deeply the battery is routinely discharged. Real capacity also falls with temperature and age, so treat the runtime as an upper bound for a new battery in mild conditions.
Spotted a figure that has moved, or a formula you can show is wrong? Tell us โ send a correction. Fixes to rates and formulas are treated as urgent.
Disclaimer
This calculator gives an estimate for guidance only. Check the figures against your own measurements or paperwork before you commit money to them.